Allen bradley 1747uic usb to dh485 usb version 1747pic slc500. Rockwell automation 1747uic universal serial bus to dh485. In the mean time, rockwell has released a firmware utility for its 1747uic which allows switching between 9,600 and. Uploaded on 4142019, downloaded 418 times, receiving a 86100 rating by 207 users. Rockwell automation releases usbtodh485 interface converter. Universal serial bus usb to dh485 interface converter 11 publication 1747 in063cenp january 2006 identify the assigned com port identify the assigned com port using device manager, as shown below. See configure the 1747uic interface converter in rslinx on page 11. There are two methods, rs232 df1 devices i tried ok with my desktop computer, and dh485 uic devices i tried ok with our laptop, if you cant communicate, please try. Before using the 1747uic, you must install drivers for both the 1747uic interface converter and the usb serial port. How to connect to an allenbradley slc 500 plc plc one. How setup a serial driver rs232 allen bradley and connect to a slc500. The drivers will be provided on a diskette with the 1747uic product. Communicate and download over dh485 using rslinx and rslogix 500.
We have also created a procedure that will be mailed on the cd with the drivers to show you the. The 1747uic has a universal serial bus usb transfer speed of 12 mbps with rslinx for free. Plc hardware allen bradley 1747uic series a, used in. If that works then you must be using the df1 driver in rslinx. Rockwell automation 1747uic universal serial bus to dh. Make sure you have a recent version of rslinx, download guide. We stick with the nonoem replacement for the 1747pic box, like the one provided with the ab micro800 plc trainer or the allen bradley 1747uic. We have updated our data protection policies based on new gdpr act.
Usb to serial chipset inside the device is the correct ftdi chipset just like in the 1747uic from ab. Aftermarket 1747uic usb dh485 usb to 1747pic for allen. When the 1747uic is used with the rs232 df1 devices driver, or the dh485 uic devices driver, df1 is communicating to the uic via a usb serial connection and not via an rs232 connection. When the installation finishes just one stage, the fdti port shows up in the device manager under usb controllers, but the 1747uic does not show up under ports. The 1747uic allows to connect devices that communicate using dh485 protocol directly to a computers usb port, using either the 1747uics rs232 or rs485 port and userprovided programming cables. Manage your ecommunications subscription preferences. Access the rockwell automation download center to keep your products current.
Buy allen bradley 1747uicusb to dh485 usb to 1747pic plc interface converter. If you are looking for a usb version of the 1747pic 1747uic then this is perfect. Enjoy more time to pay pay for your allen bradley 1747uic when its right for you. Buy allen bradley 1747 uic usb to dh485 usb to 1747 pic plc interface converter. Hello hewa, i apology for my late answer, you message went to the folder span. This usb adapter allows your laptop to connect to a dh 485 network. When the 1747 uic is used with the rs232 df1 devices driver, or the dh485 uic devices driver, df1 is communicating to the uic via a usb serial connection and not via an rs232 connection.
Get rockwell automation 1747 uic universal serial bus to dh485 interface converter manual. After a few minutes, the usb goes off, the dh flickers continuously. Example using windows 2000 configure the 1747uic interface converter in rslinx 1. Advantages embedded dh485 driver compatible with the existing. In this video we will cover the usb connection in rslinx for a allen bradley 1747 uic for windows 7 32 bit and xp and windows 7 64 bit pc this is dh485 port on 500, 501, 502 and 503 also. We stick with the nonoem replacement for the 1747 pic box, like the one provided with the ab micro800 plc trainer or the allen bradley 1747 uic specifically made to convert usb to rs484. It worked great on these fixed units as well as some 503s. Electronics free delivery possible on eligible purchases. Allenbradley 1747uic 1747uic interface module ebay. Then from the available driver types drop down list select rs232 df1 devices. This protocol requires a special usb converter, the 1747uic, which you can. Device is a little bit bulkier than the real uic but also comes with much longer cables. To regain comms youll have to edit your driver in rslinx to match the new settings. Feb 14, 2012 we purchased a 1747uic module and did some preliminary testing with an earlier version of rslinx 2.
Type in the catalog numbers andor descriptions of the products you wish to find. I get the usb light on solid, the ok solid and the dh485 will flicker randomly assuming its polling. Universal serial bus usb to dh485 interface converter 7 install the drivers before using the 1747uic, you must install drivers for both the 1747uic interface converter and the usb serial port. Open rslinx and go to communications configure drivers. Example using windows 2000 configure the 1747 uic interface converter in rslinx 1. In the mean time, rockwell has released a firmware utility for its 1747 uic which allows switching between 9,600 and. It has been rumored that a belkin usb to rs232 converter will work, but at this time we have not prove this. Alternate 32 bit method g o back to configure drivers in rslinx, delete our df1 driver, select dh485 uic devices from the drop down, and click the add new button. Aftermarket 1747uic usb dh485 usb to 1747pic for allen bradley.
Allen bradley 1747uicusb to dh485 usb to 1747pic ab plc programmer calbe. When i connect the usb cable to the pc, the found hardware popup text alternates between allenbradley 1747 uic and fdti port or something similar involving fdti. The 1747uic allows you to connect devices that communicate using dh485 protocol directly to a computers usb port, using either the 1747uics rs232 or. See below for a list of plcs that are compatible tested with windows xp sp2 and sp3 note. Slc 500 rs232 to rs485 interface converter 3 publication 1747in024aenp september 2002 current driver and rslinx release make sure you have the newest 1747pic driver and rslinx release for your operating system, particularly if you are using windows 2000, windows xp, or later operating system. First open the rslinx classic software, click the configuration driver icon or menu. Which means that your processor is configured for df1 protocol. If it isnt showing up, then navigate the the 1747uic directory or the cd when prompted. Usb with e n software an equustek dl nd select dl3 3500 df1 t 500 models. The 1747 uic usb to dh485 interface converter allows computers with usb universal serial bus ports to be connected to dh485 ports located on slc 500, micrologix, controllogix controllers, panelview terminals, as well as 1747 aic and 1761netaic isolators. If you are looking for a usb version of the 1747 pic 1747 uic then this is perfect.
We have also created a procedure that will be mailed on the cd with the drivers to show you the settings. Alternate 32 bit method you can change the name of the driver if you wish, but it can make it easier to go online if you leave it at the default. Universal serial bus usb to dh485 interface converter 11 publication 1747in063cenp january 2006 identify the assigned com port identify the assigned com port using device manager, as shown below. Usb w configuratio f2kf3 ith equu n software an stek dl35 nd select dl3 500 df1 dh 500 models. Get rockwell automation 1747uic universal serial bus to dh485 interface converter manual. Jun 12, 2019 allenbradley 1747uic 1747uic interface module. Usb 1747uic windows 7 64 and 32 bit allen bradley dh485. A straight usb to rs232 converter will not work with the pic driver.
Youre mileage will vary with the autoconfig feature. While third party 1747uics represent a great price savings versus the rockwell version, and in my own tests they work extremely well, further investigation has not been able to confirm support of multiple baud rates. Looking for a usb version of the 1747 pic then our 1747 uic is perfect and is fully compatible with windows 7, 8 and 10 32 or 64 bit if you have any issues you can call or email us for support, we also offer a full refund if you are not happy. Three led indicators on the 1747uic provide communication status. Rslogix 500 configuring rslinx serial df1 rs232 driver. The 1747uic usb to dh485 interface converter allows computers with usb universal serial bus ports to be connected to dh485 ports located on slc 500, micrologix, controllogix controllers, panelview terminals, as well as 1747aic and 1761netaic isolators. Allen bradley 1747uic installation and rslinx configuration. Allen bradley 1747uic usb to dh485 usb version 1747pic. If you have any issues you can call or email us for support, we also offer a full refund if you are not happy. We purchased a 1747uic module and did some preliminary testing with an earlier version of rslinx 2. This includes the latest addon profiles aops, drivers, macros, electronic data sheets, sample code, and software activations. Rok is a worldleading provider of industrial automation power, control and information solutions that help customers meet their manufacturing. When i connect the usb cable to the pc, the found hardware popup text alternates between allenbradley 1747uic and fdti port or something similar involving fdti. Usb dh485 rj45 or 9pin dshell, switch selectable 19200.
Usb 1747 uic windows 7 64 and 32 bit allen bradley dh485. After the programming cable is connected, first install the 1747uic driver. The converter also embeds the dh485 driver compatible with the existing rslinx df1 rs232 fullduplex driver, eliminating the need for this driver to be installed. Note that common words 1747 pi, rslinx 1747 pic aic, etc. Rockwell offers a product with a part number of 1747uic. Jun 07, 2015 hello hewa, i apology for my late answer, you message went to the folder span.
Step 6 now select 1770kf31747ke from the device drop down list. There are two methods, rs232 df1 devices i tried ok with my desktop computer, and dh485 uic devices i tried ok with our laptop, if you cant communicate, please try another way. Another example is the lesser, but growing, cip serial. Allenbradley 1747uic installation instructions manual pdf. Replace allen bradley 1747uicusb using equustek dl3500. Alternate 32 bit method go back to configure drivers in rslinx, delete our df1 driver, select dh485 uic devices from the drop down, and click the add new. Jan 24, 2018 the following procedure works with windows xp through windows 10 for 32 bit and 64 bit operating systems whether you are using the white allen bradley 1747 uic or the black 1747 uic. Buy allenbradley 1747uic is a slc 500 usb to dh485. Get 1747uic slc usb to dh485 converter at wholesale prices at westburne your electrical distributor. The following procedure works with windows xp through windows 10 for 32 bit and 64 bit operating systems whether you are using the white allen bradley 1747uic or the black 1747uic. Why the allenbradley ab 1747pic always had trouble. Configuration in rslinx uses the same dh485 uic devices driver that the ab part uses. Sep 29, 2016 this usb adapter allows your laptop to connect to a dh 485 network.
The following procedure works with windows xp through windows 10 for 32 bit and 64 bit operating systems whether you are using the white allen bradley 1747 uic or the black 1747 uic. I have applied and removed it many times on about 8 machines without any issue. When the installation finishes just one stage, the fdti port shows up in the device manager under usb controllers, but the 1747 uic does not show up under ports. We have also created a procedure that will be mailed on the cd with the drivers to show you the settings that are needed or can be found on our. You also have an option to view firmware compatibility for a given product. This is well documented on the rockwell support site.
How to connect to an allenbradley slc 500 plc dmc, inc. The 1747uic converts both electrical signalling usb to rs232 and rs485 2wire. Allen bradley 1747uic cable usb to dh485 substitute with. Allen bradley 1747uic usb to dh485 usb version 1747pic slc. The 1747uic enhances the connection of slc500, micrologix, controllogix controllers, panelview terminals, 1747aic and 1761netaic isolators through the dh485 port using a computer usb port. To select one or more products from your search listing, you. Replace allen bradley 1747uicusb using equustek dl3500df1. Allen bradley 1747 uic usb to dh485 usb to 1747 pic ab plc programmer calbe. Usb to data highway plus using the anc120e, a lower cost.
Updated and downgraded the drivers, tinkered wiht the usb settings. The converter also embeds the dh485 driver compatible with the existing rslinx df1 rs232 fullduplex driver, eliminating the need for this driver to be installed are you are using df1 driver and configuring it properly to match the target baud. Select one or more products to view the available downloads for those products. Allen bradley 1747uic usb to dh485 usb version 1747 pic slc500.